Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board for RGS090STAA0AAA — OEM Integrated Ignition Control Kit | Ships Today
ICP

ICP Furnace Control Board for RGS090STAA0AAA — OEM Integrated Ignition Control Kit | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the integrated furnace control (IFC) that manages every ignition sequence on your ICP / Tempstar / Heil RGS090STAA0AAA gas furnace. The board sequences the inducer motor, igniter, gas valve, and blower; reads the flame sensor and pressure switch; and runs the safety lockout logic. When it fails you may see no response on a call for heat, the inducer running but no ignition, the blower running continuously, erratic short-cycling, or an LED flashing a hard-lockout fault code. A cracked solder joint, a failed relay, or surge damage on this board can mimic almost any other furnace fault — making it the part to verify when symptoms don't add up.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Fitment OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil / Comfortmaker RGS090STAA0AAA 90,000 BTU gas furnace. This control platform is shared across many ICP-family RGS-series furnaces — confirm by matching OEM part number 1183618 to your existing board.

Installation Guide

  1. Safety First — Disconnect electrical power at the breaker and service switch. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before touching anything.
  4. Remove — Unplug each harness, release the board's mounting standoffs or screws, and lift the old board out.
  5. Install — Seat the new board, reconnect each harness exactly per your photo, and confirm all locking tabs click home.
  6. Test — Restore power and run a full heat cycle; confirm a clean ignition, proper blower delay, and no fault codes.

Signs You Need a Replacement

  • No response, or no ignition, on a call for heat
  • Blower or inducer runs continuously or won't start
  • Erratic short-cycling or repeated hard lockouts
  • Visible scorch marks, burnt relays, or a blank diagnostic LED

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090STAA0AAA — OEM Integrated Ignition Control Kit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090STAA0AAA — OEM Integrated Ignition Control Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090STAA0AAA — OEM Integrated Ignition Control Kit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online