This OEM integrated furnace control board kit (part 1183618) is the brain of the ICP/Heil/Tempstar RGS090SEBB0AAA gas furnace. It manages the entire heating sequence — inducer startup, hot surface igniter timing, gas valve control, flame sensing, blower fan delays, and all safety lockouts. A failed board typically presents as a dead furnace, erratic operation, blower that will not start or will not stop, or repeated ignition lockouts with no other identifiable cause. Power surges, corroded relays, and burned flame-sense circuits are the usual culprits. This genuine OEM kit ships with the correct firmware and relay configuration for your furnace, eliminating the guesswork of aftermarket boards.

Specifications

Spec Value
Part Number 1183618 (Control Board Kit)
Type Integrated Furnace Control (IFC)
Brand ICP / Heil / Tempstar
Line Voltage 120V
Control Voltage 24V
Functions Ignition, blower, gas valve, safety timing
Fit OEM Replacement

Compatibility

Designed for the ICP family RGS090SEBB0AAA gas furnace and shared across many Heil, Tempstar, Comfortmaker, and Arcoaire furnaces using the same control platform. Match the printed board number to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel to reach the control board.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer each wire to the matching terminal per your photos, and set any jumpers or DIP switches identically.
  6. Test — Restore power and run a full heat cycle, confirming proper ignition, flame sensing, and blower timing.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity
  • Blower runs continuously or fails to start
  • Repeated ignition lockouts with a good igniter and flame sensor
  • Visible burn marks, swollen capacitors, or scorched relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS090SEBB0AAA — OEM Kit 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS090SEBB0AAA — OEM Kit 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS090SEBB0AAA — OEM Kit 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online