Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board CEPL130438-01 for WFMR090C048A1 — Integrated Ignition | Ships Today
ICP

ICP Furnace Control Board CEPL130438-01 for WFMR090C048A1 — Integrated Ignition | Ships Today

SKU: 1176943 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board (part #1176943, board CEPL130438-01) is the brain of your ICP/Tempstar/Heil WFMR090C048A1 gas furnace. It manages the entire heating sequence — inducer startup, pressure-switch proving, hot-surface igniter timing, gas-valve energizing, flame sensing, and blower on/off delays — while monitoring safeties throughout the cycle. When the board fails, the furnace may ignore the thermostat, lock out on flashing diagnostic codes, fail to light, or run the blower continuously. Replacing it with a genuine OEM board restores reliable, safe ignition and proper fan timing.

Specifications

Spec Value
Part Number 1176943
Board ID CEPL130438-01
Type Integrated Ignition Control Board
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V

Compatibility

Built for the ICP/Tempstar/Heil WFMR090C048A1 furnace and other WFMR090-series units using control board CEPL130438-01. Match the CEPL number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every wire harness and terminal on the board before disconnecting.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new CEPL130438-01 board and reconnect every harness exactly as photographed.
  6. Test — Restore power and run a full heat cycle, confirming clean ignition and proper blower timing.

Signs You Need a Replacement

  • Furnace does not respond to a thermostat heat call
  • Flashing fault/lockout LED codes on the board
  • No hot-surface igniter or gas-valve activation
  • Blower runs constantly or fails to start

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WFMR090C048A1 — Integrated Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WFMR090C048A1 — Integrated Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WFMR090C048A1 — Integrated Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online