This genuine OEM ECM X-13 fan motor control (OEM #1185843) is the 1/2 HP variable-speed blower motor assembly for the ICP/Tempstar/Heil WPG3304060LKC1 package gas unit. The X-13 is a constant-torque ECM motor that maintains programmed airflow across changing static pressure, delivering quieter operation and better energy efficiency than a standard PSC motor. When this motor fails you'll typically see no blower operation, intermittent starting, error codes at the control board, or the furnace locking out on high limit because air is not moving across the heat exchanger. Replacing it with the exact OEM motor preserves the factory airflow programming and avoids the trial-and-error of a universal swap.

Specifications

Spec Value
Part Number 1185843
Type ECM X-13 Blower Motor Control
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Motor Technology Constant-Torque ECM
Application Furnace / Package Unit Blower

Compatibility

Direct fit for the ICP/Tempstar/Heil WPG3304060LKC1 package gas/electric unit and other WPG-series models that originally shipped with the 1185843 ECM X-13 motor. Always verify your existing part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter before touching wiring.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all motor and control wiring, plus the blower wheel set-screw position on the shaft.
  4. Remove — Loosen the wheel set screw, slide the blower assembly out, then unbolt the old motor and transfer the wheel to the new motor at the same depth.
  5. Install — Mount the new ECM X-13, reinstall the blower assembly, and reconnect all wiring per your photos.
  6. Test — Restore power and confirm the blower ramps and runs on each speed tap.

Signs You Need a Replacement

  • Blower will not start or runs intermittently
  • Furnace short-cycles or trips on high limit from no airflow
  • Loud humming, buzzing, or grinding from the motor
  • Control board reports a blower or airflow fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG3304060LKC1 — ECM X-13 1/2 HP Blower Motor Control | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG3304060LKC1 — ECM X-13 1/2 HP Blower Motor Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG3304060LKC1 — ECM X-13 1/2 HP Blower Motor Control | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online