Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Fan Motor for WAXM244A1 — ECM X-13 Blower Motor Control 1/3 HP | Ships Today
ICP

ICP Fan Motor for WAXM244A1 — ECM X-13 Blower Motor Control 1/3 HP | Ships Today

SKU: 1185269 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ECM X-13 blower motor control module (part number 1185269) rated at 1/3 HP for the ICP WAXM244A1 air handler. The X-13 is a constant-torque ECM that drives the indoor blower wheel along factory-programmed airflow profiles selected by jumper taps. Because it maintains a commanded torque as duct static pressure changes, it delivers more consistent airflow and better efficiency than a conventional PSC motor. Typical failure symptoms include no blower operation, intermittent or hard starting, humming without rotation, overheating, or fault codes from the air handler control. Fitting the correct OEM module restores the factory airflow tables and protects comfort and efficiency.

Specifications

Spec Value
Part Number 1185269
Type ECM X-13 Blower Motor Control
Brand ICP (Heil / Tempstar / Comfortmaker)
Horsepower 1/3 HP
Motor Technology Constant-Torque ECM
Application Indoor Air Handler / Furnace Blower
Fitment OEM Replacement

Compatibility

Engineered as the factory blower motor for the ICP WAXM244A1 air handler and the family of Heil, Tempstar, and Comfortmaker units built on the WAXM244 platform. Confirm the part number on your existing motor or control before ordering, since airflow tap programming is matched to the cabinet.

Installation Guide

  1. Safety First — Disconnect power at the breaker and unit disconnect, then verify zero voltage with a multimeter before touching wiring.
  2. Access — Remove the air handler blower compartment service panel.
  3. Document — Photograph every motor and control wire, including the airflow tap selections, before disconnecting.
  4. Remove — Disconnect the line, control, and tap harnesses, loosen the blower housing band, slide the assembly out, and transfer the wheel and set screw position to the new motor.
  5. Install — Mount the new X-13 motor, reinstall the blower wheel at the same shaft depth, reconnect every harness per your photos, and set the matching airflow taps.
  6. Test — Restore power, command a call for cooling or heating, and verify smooth start, correct rotation, and steady airflow.

Signs You Need a Replacement

  • Blower will not start or starts intermittently on a call for air
  • Humming or buzzing from the motor with little or no rotation
  • Weak or inconsistent airflow at the registers
  • Motor runs hot, trips on overload, or shuts down mid-cycle

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAXM244A1 — ECM X-13 Blower Motor Control 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAXM244A1 — ECM X-13 Blower Motor Control 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAXM244A1 — ECM X-13 Blower Motor Control 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online