This is the OEM ICP ECM X-13 blower motor control module (part number 1185290), a 1/2 HP variable-torque constant-airflow motor used as the indoor blower in ICP, Heil, and Tempstar air handlers and furnaces. The X-13 (also called Constant Torque) is an electronically commutated motor that holds a programmed torque across changing static pressure, delivering quieter operation and lower energy draw than a legacy PSC motor. When this motor fails you typically see no blower operation, intermittent or short-cycling airflow, a motor that hums but will not start, or a system that runs but never reaches setpoint because the indoor air handler is not moving air across the coil.

Specifications

Spec Value
OEM Part Number 1185290
Type ECM X-13 Blower Motor / Control Module
Brand ICP / Heil / Tempstar
Horsepower 1/2 HP
Motor Class Electronically Commutated (Constant Torque)
Application Indoor Blower / Air Handler
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Heil / Tempstar WAHL364B2 air handler. This motor is shared across several ICP-family equipment lines that use the 1/2 HP X-13 indoor blower platform. Always confirm the horsepower and the OEM part number stamped on your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the unit disconnect, then verify zero voltage at the motor leads with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all wiring, the motor mount orientation, and the blower wheel position before disconnecting.
  4. Remove — Unplug the motor harness and control connector, loosen the blower wheel set screw, remove the motor mount band/bolts, and slide the motor out of the housing.
  5. Install — Transfer the blower wheel to the new motor shaft at the same depth, mount the motor, then reconnect the power and control harness exactly per your photos.
  6. Test — Restore power, start a call for cooling or heating, and confirm smooth blower ramp-up, correct airflow, and no unusual noise or vibration.

Signs You Need a Replacement

  • Blower will not start or only hums when energized
  • Intermittent operation, surging, or short-cycling airflow
  • Weak or no airflow at the registers with the system calling
  • Burning smell, overheating, or visibly scorched windings/control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHL364B2 — 1/2 HP ECM X-13 Blower Motor Control | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHL364B2 — 1/2 HP ECM X-13 Blower Motor Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHL364B2 — 1/2 HP ECM X-13 Blower Motor Control | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online