Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Fan Coil Control Board for WAHM364A1 - OEM Replacement | Ships Today
ICP

ICP Fan Coil Control Board for WAHM364A1 - OEM Replacement | Ships Today

SKU: 1172975 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM fan coil control board (part #1172975) is the central logic board for your ICP WAHM364A1 fan coil air handler. It receives 24V thermostat calls, sequences the blower and any electric heat, drives the relays, and manages the X-13 ECM motor tap signals to deliver the correct airflow for fan, cooling, and heating modes. When the board fails, the symptoms vary widely: the blower will not start on a call, electric heat stages do not energize, the fan runs continuously or not at all, or the unit is completely unresponsive even with good 24V power present. Power surges, lightning, moisture intrusion, and failed onboard relays are the usual causes. Visible scorch marks, a cracked relay, or a burnt smell on the board confirm the failure.

Specifications

Spec Value
Part Number 1172975
Type Fan Coil Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Blower / Relay / ECM Tap Control
Application Fan Coil Air Handler
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP WAHM364A1 fan coil air handler and shared-platform Tempstar, Heil, and Comfortmaker WAHM-series units using the 1172975 fan coil control board. Verify your existing board carries the same part number and connector layout before installing.

Installation Guide

  1. Safety First - Disconnect power at the breaker and verify zero voltage with a multimeter at the board's line and 24V terminals.
  2. Access - Remove the air handler control compartment panel.
  3. Document - Photograph every wire and connector on the board before disconnecting anything.
  4. Remove - Unplug all harnesses and low-voltage leads, then unscrew the failed board from its standoffs.
  5. Install - Mount the new board on the standoffs and reconnect every harness and lead exactly per your photo.
  6. Test - Restore power and verify correct blower, heat, and cooling response to each thermostat call.

Signs You Need a Replacement

  • Blower will not start on a valid thermostat call
  • Electric heat stages fail to energize
  • Fan runs continuously or the unit is fully unresponsive with good 24V power
  • Visible scorch marks, a burnt smell, or a failed relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WAHM364A1 - OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WAHM364A1 - OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WAHM364A1 - OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.