This OEM fan coil control board (part number 1172975) is the main low-voltage control module for your ICP WAHM302A1 air handler. The board interprets thermostat calls, sequences the ECM blower, manages electric heat staging, and routes 24V power throughout the unit. When a control board fails the symptoms are often intermittent and confusing — the blower may not start, auxiliary heat may not engage, the system may short-cycle, or it may stop responding to the thermostat entirely. Burnt relays, scorched traces, blown onboard fuses, or heat damage around the terminals are clear indicators the board has failed and needs replacement.

Specifications

Spec Value
Part Number 1172975
Type Fan Coil Control Board
Brand ICP (Tempstar / Heil)
Function Blower / Heat Staging / 24V Control
Control Voltage 24 VAC
Application Indoor Air Handler / Fan Coil
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP WAHM302A1 air handler. As ICP manufactures the Tempstar, Heil, Comfortmaker, and Arcoaire brands, this fan coil control board also services comparable WAHM-series fan coils built on the same control platform. Confirm part number 1172975 and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the air handler control-compartment service panel.
  3. Document — Photograph every harness, thermostat wire, and plug connected to the board before disconnecting.
  4. Remove — Unplug all connectors and thermostat leads, then unscrew or unclip the board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each harness and thermostat wire exactly per your photos.
  6. Test — Restore power and verify the blower, heat staging, and thermostat response all operate normally.

Signs You Need a Replacement

  • Blower or electric heat will not energize on a thermostat call.
  • System short-cycles or ignores the thermostat intermittently.
  • Visible burnt relays, scorched traces, or a blown onboard fuse.
  • No 24V output to the blower or heat circuits despite good incoming control power.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WAHM302A1 — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WAHM302A1 — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WAHM302A1 — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online