Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Fan Coil Control Board for WAHM244A1 — OEM Direct Fit | Ships Today
ICP

ICP Fan Coil Control Board for WAHM244A1 — OEM Direct Fit | Ships Today

SKU: 1172975 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is an OEM fan coil control board (part number 1172975) for the ICP WAHM244A1 fan coil / air handler. The control board is the brain of the unit — it interprets thermostat calls, sequences the blower motor and electric heat stages, manages safety interlocks, and coordinates the 24V control circuit. When the board fails, the air handler may stop responding to the thermostat, run the blower continuously, fail to energize heat, or behave erratically. Visible scorch marks, blown fuses, burnt relays, or a board that will not power up are clear indicators that the control board has failed and needs replacement.

Specifications

Spec Value
Part Number 1172975
Type Fan Coil Control Board
Brand ICP (Tempstar / Heil)
Function Blower & Heat Sequencing, 24V Control
Application Fan Coil / Air Handler
Fitment OEM Direct Replacement

Compatibility

Built as a direct-fit replacement for the ICP WAHM244A1 fan coil. This control board is shared across many ICP-family air handlers sold under the Tempstar, Heil, and Comfortmaker brands. Confirm OEM part number 1172975 against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before servicing.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every wire harness and terminal connection on the board before disconnecting anything.
  4. Remove — Unplug all connectors, release the mounting standoffs or screws, and lift out the failed board.
  5. Install — Seat the new board on the mounts and reconnect every harness and terminal exactly per your photos.
  6. Test — Restore power, run a heat and a fan call, and confirm the board sequences the blower and heat correctly.

Signs You Need a Replacement

  • Air handler does not respond to thermostat calls
  • Blower runs continuously or will not start
  • Electric heat will not energize or stages erratically
  • Visible burn marks, blown fuse, or board will not power up

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WAHM244A1 — OEM Direct Fit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WAHM244A1 — OEM Direct Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WAHM244A1 — OEM Direct Fit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart