Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Motor Control Module for WPH4244000RKA1 — 1/2 HP | Ships Today
ICP

ICP ECM X-13 Motor Control Module for WPH4244000RKA1 — 1/2 HP | Ships Today

SKU: WPH4244000RKA1 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ECM X-13 motor control module (part number 1185842) is the electronic control that drives the 1/2 HP X-13 constant-torque blower motor in your ICP/Tempstar/Heil WPH4244000RKA1 system. The X-13 platform uses a programmed control module mated to the motor to deliver consistent airflow across changing static pressure, improving efficiency and comfort over a standard PSC motor. The control module is the most failure-prone part of an ECM assembly because it carries the electronics and power stage. Symptoms of a failing module include a blower that won't run, runs at the wrong speed, surges, or shuts down intermittently, often with no error at the thermostat. Replacing the module restores proper operation without swapping the entire motor when the rotor is still good.

Specifications

Spec Value
Part Number 1185842
Type ECM X-13 Motor Control Module
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Motor Platform X-13 constant torque

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil WPH4244000RKA1 and other systems using the matched 1/2 HP X-13 ECM motor. The control module must match the motor it programs — verify the original part number before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the line, neutral, ground, and low-voltage control connections.
  4. Remove — Unplug the harness connectors and separate the control module from the motor end bell.
  5. Install — Seat the new module onto the motor, reconnect every harness per your photos.
  6. Test — Restore power and confirm the blower ramps to the correct speed on a call for heat/cool/fan.

Signs You Need a Replacement

  • Blower motor will not start or spins then stops
  • Airflow is weak, surging, or stuck at one speed
  • Intermittent blower operation with no thermostat fault
  • Burnt smell or visible scorching on the control module

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPH4244000RKA1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPH4244000RKA1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPH4244000RKA1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online