Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Motor Control Module for WAPL424A1 — 1/2 HP | Ships Today
ICP

ICP ECM X-13 Motor Control Module for WAPL424A1 — 1/2 HP | Ships Today

SKU: 1185291 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ECM X-13 motor control module (part #1185291) is the electronic control for the 1/2 HP constant-torque blower motor in your ICP WAPL424A1 air handler. The X-13 platform delivers programmed, energy-efficient airflow across multiple tap settings selected by the control board. When the module fails, the blower may run erratically, stay off entirely, hunt between speeds, or trip on internal faults — leaving you with no air movement and inconsistent heating or cooling. Because the control is the brain of the ECM motor, a failed module is a common cause of "motor won't start" complaints even when the motor windings are good.

Specifications

Spec Value
Part Number 1185291
Type ECM X-13 Motor Control Module
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Motor Style Constant-Torque ECM (X-13)
Application Furnace / Air Handler Blower

Compatibility

A direct OEM fit for the ICP WAPL424A1 and matching Tempstar, Heil, Day & Night, Comfortmaker, KeepRite, and Arcoaire systems using the 1/2 HP ECM X-13 blower platform. Confirm the horsepower rating and X-13 control style against your existing module before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before servicing the motor.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the line-voltage, ground, and the low-voltage tap/control connections before disconnecting.
  4. Remove — Unplug the control connectors, then separate the control module from the motor end shield.
  5. Install — Mate the new X-13 control to the motor, reconnect all plugs per your photo, and confirm the tap selection matches the original.
  6. Test — Restore power and verify the blower ramps up and runs smoothly on each call.

Signs You Need a Replacement

  • Blower motor will not start despite a call for heating or cooling.
  • Motor surges, hunts, or runs at the wrong speed.
  • Intermittent operation or unexpected shutdowns mid-cycle.
  • No airflow at the registers with the motor itself testing good.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAPL424A1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAPL424A1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAPL424A1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online