Overview

This is the OEM ECM X-13 motor control module for the ICP / Tempstar / Heil WJA342000KTP0B1, OEM part number 1185846 (ECM X-13 MTR CONTROL 1/2 HP). The X-13 is a constant-torque electronically commutated motor (ECM) control rated at 1/2 HP that drives the indoor blower at programmed speed taps. It is far more efficient than a legacy PSC motor and holds airflow steady against changing static pressure. The control module is the electronics end of the ECM assembly — when it fails the blower runs erratically, sticks on one speed, or stops entirely, producing weak airflow, no-heat / no-cool comfort complaints, or blower-fault codes at the furnace control board.

Specifications

Spec Value
OEM Part Number 1185846
Type ECM X-13 Constant-Torque Motor Control
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Application Indoor blower / air handler
Fitment OEM direct replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil model WJA342000KTP0B1. The 1/2 HP ECM X-13 control is used across numerous ICP-family furnaces and air handlers built on the X-13 blower platform. Confirm horsepower, the X-13 designation, and the speed-tap configuration against your existing module before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the blower-compartment service panel and slide out the blower assembly if needed.
  3. Document — Photograph the high-voltage harness and the low-voltage speed-tap plug positions before disconnecting.
  4. Remove — Unplug the power and control connectors, then separate the failed control module from the motor end shield.
  5. Install — Fit the new X-13 control to the motor, reconnect the power harness and speed-tap plug exactly per your photo.
  6. Test — Restore power and confirm the blower ramps to the correct speed on a heat and cool call.

Signs You Need a Replacement

  • Blower runs intermittently, surges, or will not start.
  • Weak or no airflow despite a clean filter and open registers.
  • Blower stuck on a single speed regardless of heat/cool demand.
  • Furnace control board reporting a blower or motor fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJA342000KTP0B1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJA342000KTP0B1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJA342000KTP0B1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.