Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Motor Control for WAPT304A1 — 1/3 HP | Ships Today
ICP

ICP ECM X-13 Motor Control for WAPT304A1 — 1/3 HP | Ships Today

SKU: 1185271 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ECM X-13 blower motor control (ICP part #1185271) is the 1/3 HP electronically commutated motor for the ICP / Tempstar / Heil WAPT304A1 system. Unlike a standard PSC motor, the X-13 ECM uses a built-in electronic control module to hold a programmed, constant-torque airflow across varying static pressure — delivering quieter, more efficient operation and steadier airflow. Failure symptoms include the blower not starting, surging or hunting airflow, the motor running only briefly before shutting down, or fault codes at the control board. ECM failures usually trace to the integrated control module, bearing wear, or moisture intrusion. A genuine OEM X-13 replacement restores the system's programmed airflow profile and efficiency.

Specifications

Spec Value
Part Number 1185271
Type ECM X-13 Blower Motor with Control
Brand ICP (Tempstar / Heil)
Horsepower 1/3 HP
Motor Technology Constant-torque ECM (X-13)
Application Furnace blower / air handler

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil WAPT304A1 air handler. Verify horsepower, the X-13 motor program, and the existing part number before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the line-voltage leads, low-voltage tap connections, and blower-wheel set-screw position.
  4. Remove — Loosen the wheel set screw, unplug the motor and control connectors, and unbolt the motor from the housing.
  5. Install — Mount the new X-13 motor, reset the wheel position, and reconnect line and control leads exactly per your photos.
  6. Test — Restore power and confirm the blower ramps to the correct programmed airflow.

Signs You Need a Replacement

  • Blower will not start or starts then immediately stops.
  • Surging, hunting, or inconsistent airflow.
  • Control board reports a blower or motor fault.
  • Bearing noise or signs of moisture/corrosion on the control module.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAPT304A1 — 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAPT304A1 — 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAPT304A1 — 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online