Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Fan Motor for WPA3244000RKC1 — 1/2 HP | Ships Today
ICP

ICP ECM X-13 Fan Motor for WPA3244000RKC1 — 1/2 HP | Ships Today

SKU: 1185842 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ECM X-13 motor control (part number 1185842) is the 1/2 HP variable-speed blower motor used in the ICP WPA3244000RKC1 air handler/blower section. X-13 motors are constant-torque ECM (electronically commutated) motors that deliver quieter operation, lower energy use, and better airflow consistency than legacy PSC motors. The integrated control module reads the tap selected by the furnace or air handler board and holds a programmed torque to maintain airflow across changing static pressure. Common failure symptoms include a blower that won't start, intermittent operation, a motor that runs hot and cycles on thermal overload, error codes from the control board, or unusual humming and no rotation. Because the module and motor are matched as an assembly, replacing with the correct OEM X-13 unit ensures proper torque tables and tap response.

Specifications

Spec Value
Part Number 1185842
Type ECM X-13 Constant-Torque Motor Control
Brand ICP / Heil / Tempstar / Comfortmaker
Horsepower 1/2 HP
Motor Technology Electronically Commutated (ECM)
Application Furnace / Air Handler Blower
Fits Model WPA3244000RKC1

Compatibility

Direct OEM replacement for the 1/2 HP ECM X-13 blower motor in the ICP/Heil/Tempstar/Comfortmaker WPA3244000RKC1. Verify horsepower, motor diameter, shaft size, rotation, and the multi-pin control connector against your existing assembly before installing, as X-13 motors are programmed for specific equipment torque profiles.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly.
  3. Document — Photograph the line voltage plug, the control plug, and the selected speed taps before disconnecting.
  4. Remove — Mark the blower wheel set-screw position, loosen it, pull the old motor from the housing, and transfer the wheel and mounting band.
  5. Install — Mount the new X-13 motor, reinstall the blower wheel at the same depth, and reconnect the line and control plugs per your photos.
  6. Test — Restore power and run the blower on each call (heat, cool, fan) to confirm proper ramp-up and airflow.

Signs You Need a Replacement

  • Blower won't start or runs intermittently
  • Motor overheats and trips on thermal overload
  • Humming with no rotation or wrong direction
  • Weak airflow or control-board fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPA3244000RKC1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPA3244000RKC1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPA3244000RKC1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online