Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Fan Motor Control for WJH330000KTP0A2 — 1/3 HP Variable Speed Blower | Ships Today
ICP

ICP ECM X-13 Fan Motor Control for WJH330000KTP0A2 — 1/3 HP Variable Speed Blower | Ships Today

SKU: 1185840 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ECM X-13 motor control / blower motor (part #1185840) rated at 1/3 HP for ICP, Tempstar, and Heil systems. The X-13 is a constant-torque electronically commutated motor (ECM) that delivers programmed airflow across changing static pressure, running cooler and quieter than a standard PSC motor while cutting energy use. It drives the indoor blower wheel that moves conditioned air through your ductwork. When an X-13 control fails you'll typically see no blower operation, intermittent starting, the motor humming without spinning, or error codes on the furnace control board.

Specifications

Spec Value
Part Number 1185840
Type ECM X-13 Constant Torque Motor Control
Brand ICP / Tempstar / Heil
Horsepower 1/3 HP
Voltage 230V
Application Indoor Blower / Air Handler
Fitment OEM Replacement

Compatibility

Designed as the direct OEM replacement for the indoor blower motor control in ICP/Tempstar/Heil model WJH330000KTP0A2 and equivalent units sharing the 1185840 motor. Always verify your motor part number and program plug before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the motor wiring, mounting orientation, and program/tap plug position before disconnecting.
  4. Remove — Disconnect the power and control harness, unbolt the motor mount band, slide the motor from the blower housing, and transfer the blower wheel and set screw.
  5. Install — Mount the blower wheel to the new motor shaft, secure in the housing, reconnect harness and program plug exactly per your photos.
  6. Test — Restore power and confirm the blower ramps to the correct speed on a call for heat and cool.

Signs You Need a Replacement

  • Blower will not start or runs only intermittently
  • Motor hums or buzzes but the wheel does not turn
  • Weak or inconsistent airflow at the registers
  • Furnace board throws a blower/communication fault code

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH330000KTP0A2 — 1/3 HP Variable Speed Blower | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJH330000KTP0A2 — 1/3 HP Variable Speed Blower | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH330000KTP0A2 — 1/3 HP Variable Speed Blower | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online