Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Fan Motor Control for WAHA30114A1 — 1/3 HP | Ships Today
ICP

ICP ECM X-13 Fan Motor Control for WAHA30114A1 — 1/3 HP | Ships Today

SKU: 1185274 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ECM X-13 motor control (part number 1185274), a 1/3 HP constant-torque variable-speed blower motor used in ICP, Tempstar, and Heil air handlers and fan coils. The X-13 platform delivers programmed constant airflow across changing static pressure, improving comfort and efficiency over a traditional PSC motor. When this motor or its integrated control fails, the blower may run intermittently, fail to start, hum without spinning, or trip on thermal overload. Replacing it with the correct OEM 1/3 HP X-13 control restores proper airflow staging and quiet operation.

Specifications

Spec Value
Part Number 1185274
Type ECM X-13 Motor Control
Brand ICP (Tempstar / Heil)
Horsepower 1/3 HP
Motor Technology Constant-torque variable-speed ECM
Application Furnace blower / air handler

Compatibility

Designed as the OEM blower motor control for the ICP / Tempstar / Heil WAHA30114A1 air handler. It also fits the WAHA series of fan coils that originally shipped with the 1185274 X-13 control. Always confirm your existing motor part number and HP before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the unit with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all motor and control wiring, including the tap connections, before disconnecting.
  4. Remove — Unplug the motor harness, remove the blower assembly, loosen the set screw, and pull the old X-13 motor from the housing.
  5. Install — Mount the new 1/3 HP motor in the blower housing, transfer the wheel and set screw, reinstall the assembly, and reconnect the harness exactly per your photos.
  6. Test — Restore power and verify the blower ramps to programmed speed on a call for fan/heat/cool.

Signs You Need a Replacement

  • Blower won't start or only hums when energized
  • Motor spins briefly then shuts off on thermal overload
  • Weak or inconsistent airflow at the registers
  • Burning smell or visible scorching at the motor control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHA30114A1 — 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHA30114A1 — 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHA30114A1 — 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online