Overview

This OEM ECM X-13 motor control module (part #1185842) is the 1/2 HP constant-torque electronic blower control used in ICP, Tempstar, and Heil air handlers and heat pumps such as the WPH3244000RKC1. The X-13 is a programmed constant-torque ECM that delivers efficient, quiet airflow across multiple tap-selected speeds. The control module is the brain of the motor — it interprets the 24V tap signals and drives the windings. A failed module typically presents as a blower that will not run, runs at the wrong speed, or hums without starting. Replacing the X-13 control restores proper airflow for both heating and cooling operation.

Specifications

Spec Value
Part Number 1185842
Type ECM X-13 Constant-Torque Motor Control
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Application Blower / Air Handler
Fit OEM Replacement

Compatibility

Fits ICP, Tempstar, Heil, and Comfortmaker air handlers and heat pumps using the 1/2 HP X-13 ECM blower platform, including model WPH3244000RKC1. Match horsepower and the connector/tap configuration to your existing motor control before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph the 5-pin power plug, the 24V control taps, and the motor orientation before disconnecting.
  4. Remove — Unplug the power and control harnesses, remove the control module retaining screws, and separate the control from the motor end shield.
  5. Install — Seat the new X-13 control on the motor, secure it, and reconnect the power plug and tap signals exactly per your photo.
  6. Test — Replace the panel, restore power, and run a heat and cool cycle to confirm correct blower speed.

Signs You Need a Replacement

  • Blower will not start or only hums
  • Motor runs at a single wrong speed regardless of tap
  • Intermittent blower operation or random shutdowns
  • Burnt-electronics smell or visible scorching on the control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPH3244000RKC1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPH3244000RKC1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPH3244000RKC1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.