Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Blower Motor Control for WPG3244060LKC1 — 1/2 HP | Ships Today
ICP

ICP ECM X-13 Blower Motor Control for WPG3244060LKC1 — 1/2 HP | Ships Today

SKU: 1185842 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ECM X-13 blower motor control is the 1/2 HP constant-torque variable-speed motor that drives the indoor blower in the ICP WPG3244060LKC1 packaged gas/electric unit. Unlike a standard PSC motor, the X-13 ECM uses a programmed electronic control module to hold a steady torque across changing static pressure, delivering quieter operation and better airflow consistency. When the motor or its integrated control fails you'll see no blower at all, intermittent operation, surging or hunting airflow, or the motor humming without spinning. This listing covers the ECM X-13 motor control assembly, 1/2 HP (OEM 1185842).

Specifications

Spec Value
Part Number 1185842
Type ECM X-13 constant-torque blower motor with control
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Motor Technology Electronically commutated (ECM), multi-tap programmed

Compatibility

Direct-fit replacement for the ICP WPG3244060LKC1 and related ICP, Tempstar, Heil, and Comfortmaker units that use the 1/2 HP X-13 ECM blower motor. Confirm horsepower, rotation, shaft size, and the programmed tap selection match your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the motor connections with a multimeter.
  2. Access — Remove the blower compartment service panel and slide out the blower assembly if needed.
  3. Document — Photograph the power harness, the control/tap plug, and the blower wheel set-screw position before disturbing anything.
  4. Remove — Disconnect the harness and tap plug, loosen the wheel set screw, pull the wheel, and unbolt the motor from the mount.
  5. Install — Bolt in the new motor, transfer the blower wheel and set its position per your photo, then reconnect the power harness and tap plug.
  6. Test — Restore power, run heat and cool calls, and confirm the blower ramps to steady airflow without surging.

Signs You Need a Replacement

  • Blower does not run on any heat or cool call.
  • Motor hums or hesitates but will not spin up.
  • Airflow surges, hunts, or cuts in and out intermittently.
  • Motor overheats, smells burnt, or trips the breaker.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG3244060LKC1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG3244060LKC1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG3244060LKC1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online