Overview

This is a genuine OEM ECM X-13 blower motor control (Part #1185845), rated 1/2 HP, for the ICP/Tempstar/Heil WJH336000K000A1 air handler. The X-13 is a constant-torque electronically commutated motor that drives the indoor blower wheel, moving conditioned air through the duct system. Compared to a standard PSC motor, the X-13 delivers steadier airflow and lower electrical consumption across multiple programmed taps. When this motor fails, the system loses indoor airflow entirely or runs erratically, leading to poor comfort, frozen coils, or overheating safety lockouts.

Specifications

Spec Value
Part Number 1185845
Type ECM X-13 Constant-Torque Blower Motor
Brand ICP / Tempstar / Heil
Horsepower 1/2 HP
Application Indoor Blower / Air Handler
Control Multi-tap programmed motor control
Fitment OEM Replacement

Compatibility

Factory-correct blower motor control for the ICP/Tempstar/Heil WJH336000K000A1, and a direct replacement for ICP-family air handlers and furnaces specifying the 1/2 HP X-13 motor. Confirm horsepower, shaft size, rotation, and mounting before installing.

Installation Guide

  1. Safety First – Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access – Remove the blower compartment service panel.
  3. Document – Photograph the motor wiring, tap selection, and blower wheel position before disconnecting.
  4. Remove – Unplug the motor connectors, loosen the blower wheel set screw, and pull the old motor from the housing.
  5. Install – Mount the new X-13 motor, reinstall the blower wheel at the correct depth, and reconnect the harness to the matching taps per your photo.
  6. Test – Restore power and verify smooth start-up and proper airflow on each stage.

Signs You Need a Replacement

  • Blower won't start, or hums without spinning.
  • Weak, intermittent, or no indoor airflow.
  • Frozen evaporator coil from insufficient air movement.
  • Motor runs hot, cycles on thermal overload, or makes grinding/bearing noise.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH336000K000A1 – 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJH336000K000A1 – 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH336000K000A1 – 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.