Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Blower Motor Control for WJH330000K000A2 — 1/3 HP | Ships Today
ICP

ICP ECM X-13 Blower Motor Control for WJH330000K000A2 — 1/3 HP | Ships Today

SKU: 1185840 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ECM X-13 motor control module (part number 1185840) for the ICP Tempstar Heil WJH330000K000A2 air handler/heat pump. The X-13 is a constant-torque electronically commutated motor (ECM) rated at 1/3 HP, used to drive the indoor blower. The motor control is the electronic module bolted to the end of the motor that converts the incoming power and 24V taps into the commutated drive signals that spin the rotor at the selected torque profile. ECM blower motors run far more efficiently than older PSC motors, but their control modules are sensitive to power surges, moisture, and overheating — and the module is the component that most often fails first.

Specifications

Spec Value
Part Number 1185840
Type ECM X-13 Constant-Torque Motor Control
Brand ICP / Tempstar / Heil
Horsepower 1/3 HP
Application Indoor Blower Motor
Fits Model WJH330000K000A2
Fitment Genuine OEM replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil WJH330000K000A2 and related WJH-series units using a 1/3 HP ECM X-13 blower motor control. The X-13 module must match the motor it mounts to — confirm part number 1185840 and the 1/3 HP rating against your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter; wait several minutes for the module to discharge.
  2. Access — Remove the blower compartment panel and slide out the blower assembly if needed.
  3. Document — Photograph the high-voltage plug and the 24V tap connections before disconnecting.
  4. Remove — Unplug both connectors, remove the bolts securing the control to the motor, and separate the module.
  5. Install — Attach the new control to the motor end-shield, then plug in the power and 24V tap connectors exactly per your photo.
  6. Test — Restore power, call for blower operation, and verify the motor ramps to the correct speed on each tap.

Signs You Need a Replacement

  • Blower won't start, or hums and jogs without spinning up
  • Intermittent operation or motor cycling on and off
  • No airflow despite a confirmed 24V call to the motor
  • Burnt smell or visible damage on the control module

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH330000K000A2 — 1/3 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJH330000K000A2 — 1/3 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH330000K000A2 — 1/3 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online