Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Blower Motor Control for WAHT424B1 — 1/2 HP | Ships Today
ICP

ICP ECM X-13 Blower Motor Control for WAHT424B1 — 1/2 HP | Ships Today

SKU: 1185291 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM ECM X-13 motor control module rated 1/2 HP (part number 1185291) for the ICP WAHT424B1 air handler. The X-13 is a constant-torque electronically commutated motor (ECM) that drives the blower at programmed torque levels, delivering quieter, more efficient airflow than a standard PSC motor. The control module is the electronics package that powers and commutates the motor windings. When the X-13 control fails, the blower may not spin, run at the wrong speed, surge, or shut down intermittently — and you may hear clicking or smell hot electronics. Bearing drag, a burned control board, or a stalled rotor are common failure modes.

Specifications

Spec Value
Part Number 1185291
Type ECM X-13 Motor Control (Constant Torque)
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Motor Technology Electronically Commutated (ECM)
Application Air Handler Blower

Compatibility

Engineered as a direct OEM fit for the ICP WAHT424B1 air handler and other Tempstar, Heil, and Comfortmaker fan coil units that use the 1/2 HP X-13 motor part 1185291. Match the horsepower and part number to your existing motor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter; ECM modules hold a charge, so wait several minutes before handling.
  2. Access — Remove the air handler service panel and slide out the blower assembly.
  3. Document — Photograph the motor harness, power connector, and blower wheel position before disconnecting.
  4. Remove — Unplug the 5-pin control and power connectors, loosen the blower wheel set screw, and separate the motor from the housing.
  5. Install — Mount the new X-13 motor, reinstall the blower wheel at the correct depth, and reconnect both connectors per your photo.
  6. Test — Restore power, run a blower call, and confirm smooth, correct-speed operation with no surging.

Signs You Need a Replacement

  • Blower will not start or only hums without spinning
  • Motor runs at the wrong speed, surges, or cycles on and off
  • Clicking, grinding, or a hot electronics odor from the blower
  • Intermittent airflow or repeated blower fault lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHT424B1 — 1/2 HP | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHT424B1 — 1/2 HP | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHT424B1 — 1/2 HP | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online