ICP ECM X-13 Blower Motor Control 1/3 HP for WJH324000KTP0A1 — Same-Day Shipping
ICP

ICP ECM X-13 Blower Motor Control 1/3 HP for WJH324000KTP0A1 — Same-Day Shipping

SKU: 1185839 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ICP ECM X-13 motor control module (part number 1185839), a 1/3 HP variable-speed blower motor control used in ICP, Heil, and Tempstar heat pump air handlers and furnaces. The X-13 is a constant-torque ECM platform that maintains programmed airflow across changing static pressure, delivering quieter, more efficient blower operation than a traditional PSC motor. When the X-13 control fails you will typically see no blower operation, intermittent startup, surging or hunting airflow, or fault codes at the control board. Replacing the control module restores correct CFM staging for both heating and cooling modes.

Specifications

Spec Value
Part Number 1185839
Type ECM X-13 Motor Control
Brand ICP (Heil / Tempstar)
Horsepower 1/3 HP
Motor Platform Constant-Torque ECM
Application Blower / Air Handler
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for ICP model WJH324000KTP0A1 and related Heil, Tempstar, and Comfortmaker heat pump air handlers using the 1/3 HP X-13 ECM blower platform. Always confirm the part number on your existing motor control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph all motor, control board, and tap connections before disconnecting anything.
  4. Remove — Unplug the 5-pin/16-pin ECM connectors, disconnect line voltage, and unbolt the motor control module from the blower housing.
  5. Install — Mount the new X-13 control, reconnect each plug and program tap exactly per your photos.
  6. Test — Restore power and verify the blower ramps to correct speed in both heat and cool calls.

Signs You Need a Replacement

  • Blower will not start or starts only intermittently
  • Airflow surges, hunts, or runs at the wrong speed
  • Burning smell or visible scorching on the control module
  • Furnace/air handler throws a blower or communication fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH324000KTP0A1 — Same-Day Shipping?
Yes. This is the factory-specified OEM fan motor for the ICP WJH324000KTP0A1 — Same-Day Shipping. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH324000KTP0A1 — Same-Day Shipping?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online