This OEM ICP ECM X-13 motor control (part number 1185282) is the 1/3 HP variable-efficiency blower motor used in the WAHT304A2 air handler. The X-13 is a constant-torque ECM (electronically commutated motor) that delivers higher efficiency and quieter, more consistent airflow than a standard PSC motor while responding to discrete tap selections from the control board. When an X-13 motor fails, you'll see no airflow, a motor that hums but won't spin, intermittent dropouts, or fault codes at the control board. The onboard module is the common failure point. Replacing it with the correct OEM 1/3 HP X-13 control restores proper, efficient blower operation.

Specifications

Spec Value
Part Number 1185282
Type ECM X-13 Constant-Torque Blower Motor Control
Brand ICP (Tempstar / Heil / Comfortmaker)
Horsepower 1/3 HP
Motor Technology ECM X-13 (electronically commutated)
Application Air handler / furnace blower

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WAHT304A2 air handler and equivalent Comfortmaker fan coil units built around the X-13 ECM platform. Confirm horsepower (1/3 HP), the X-13 motor technology, and the shaft/mounting and connector configuration against your existing motor before installing — X-13 controls are tap-programmed and not interchangeable with PSC motors.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching the motor.
  2. Access — Remove the air handler service panel and slide out the blower assembly.
  3. Document — Photograph the X-13 tap connections, line-voltage leads, and the blower wheel position on the shaft.
  4. Remove — Loosen the wheel set screw, pull the wheel, unplug the control connectors, and unbolt the old motor from the housing.
  5. Install — Mount the new motor, reinstall the wheel at the documented depth, tighten the set screw on the shaft flat, and reconnect the tap and power leads exactly per your photo.
  6. Test — Restore power and verify the blower ramps up quietly and delivers strong airflow on each active tap.

Signs You Need a Replacement

  • No airflow, or a motor that hums but won't start
  • Blower drops out intermittently or won't hold speed
  • Control board throws a blower or motor fault code
  • Burnt smell or visible damage at the motor's electronics module

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WAHT304A2 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WAHT304A2 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WAHT304A2 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.