Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 Blower Motor Control 1/2 HP for WPG3304040RKC1 | Ships Today
ICP

ICP ECM X-13 Blower Motor Control 1/2 HP for WPG3304040RKC1 | Ships Today

SKU: 1185843 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ECM X-13 blower motor control (part number 1185843) for the ICP / Tempstar / Heil WPG3304040RKC1. The X-13 is a 1/2 HP constant-torque electronically commutated motor that delivers far better efficiency and quieter, more consistent airflow than a traditional PSC blower. The motor control module is integrated and pre-programmed for the unit's tap settings. When an X-13 motor fails it typically will not start, runs only on one tap, surges, or throws a blower fault — leaving the system with no indoor airflow and triggering high-limit or pressure-switch lockouts. Installing the correct OEM motor restores designed airflow and protects the heat exchanger and coil from overheating.

Specifications

Spec Value
Part Number 1185843
Type ECM X-13 Constant-Torque, Blower
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Control Integrated motor control module
Fits Model WPG3304040RKC1

Compatibility

Engineered for the ICP WPG3304040RKC1 and shared across many Tempstar, Heil, Comfortmaker, and Day & Night air handlers and packaged units that use a 1/2 HP ECM X-13 blower motor. Confirm horsepower, rotation, and tap configuration against your original motor.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before touching the blower assembly.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph the power harness, control plug, and tap wiring before disconnecting.
  4. Remove — Pull the blower assembly, mark the wheel set screw position, loosen it, and slide the old motor out of the housing.
  5. Install — Mount the new X-13 motor, set the blower wheel to the original depth, reconnect the harness and tap leads per your photo.
  6. Test — Restore power, run a heat and cool cycle, and verify the blower ramps to full speed on each tap.

Signs You Need a Replacement

  • Blower will not start or only starts intermittently
  • Weak, surging, or single-speed airflow
  • Furnace short-cycles on high limit due to low airflow
  • Grinding bearing noise or motor running hot to the touch

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG3304040RKC1 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG3304040RKC1 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG3304040RKC1 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera