Overview

This is the OEM 1/2 HP ECM X-13 motor control (part number 1185843) for the ICP / Tempstar / Heil WPA3304000RKC1 unit. The X-13 is a constant-torque electronically commutated motor that drives the indoor blower at programmed speed taps, delivering quiet operation and far better efficiency than a standard PSC motor. When this motor fails, the blower may not run, may run at the wrong speed, or may start and stop intermittently — leaving the system with weak airflow, poor heating/cooling, or nuisance lockouts. This factory replacement restores correct, efficient airflow across all speed settings.

Specifications

Spec Value
Part Number 1185843
Type ECM X-13 Constant-Torque Motor Control
Horsepower 1/2 HP
Application Indoor Blower
Brand ICP (Tempstar / Heil)
Fits Model WPA3304000RKC1
Fitment OEM Direct Replacement

Compatibility

Factory replacement blower motor control for the ICP / Tempstar / Heil WPA3304000RKC1 unit. Confirm horsepower (1/2 HP) and the X-13 motor type against your existing motor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before servicing.
  2. Access — Remove the blower service panel and slide out the blower assembly if needed.
  3. Document — Photograph the high-voltage harness, the 24V speed-tap connector, and the blower wheel position on the shaft.
  4. Remove — Disconnect the harnesses, loosen the wheel set screw, and unbolt the old motor from the housing.
  5. Install — Mount the new motor, set the blower wheel to the same position, and reconnect both harnesses per your photo.
  6. Test — Restore power and confirm the blower ramps to the correct speed on heating and cooling calls.

Signs You Need a Replacement

  • Blower does not run despite a valid call and good control signal
  • Weak or inconsistent airflow at the registers
  • Motor starts then stops, or hunts between speeds
  • Overheating, burning smell, or noisy bearings from the motor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPA3304000RKC1 — OEM 1185843 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPA3304000RKC1 — OEM 1185843 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPA3304000RKC1 — OEM 1185843 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.