This OEM ECM X-13 motor with integrated control drives the blower in your ICP WPG3304040LKC1 system, moving conditioned air through the ductwork on both heating and cooling calls. The X-13 is a constant-torque electronically commutated motor (1/2 HP) that delivers higher efficiency and quieter, programmed-tap airflow than a standard PSC motor. When the motor or its onboard control fails, the blower may not spin, run at the wrong speed, cycle on overload, or fail to respond to the board's tap signal — leading to poor airflow, comfort complaints, or high-limit trips. This listing includes the ECM X-13 motor control module (OEM 1185843). Confirm the correct programmed tap and rotation before installing.

Specifications

Spec Value
Part Number 1185843
Type ECM X-13 Constant-Torque Blower Motor w/ Control
Brand ICP (Tempstar / Heil)
Horsepower 1/2 HP
Application Furnace / Air Handler Blower
Fit OEM Replacement

Compatibility

Engineered for the ICP / Tempstar / Heil WPG3304040LKC1 packaged unit and related ICP-family equipment using a 1/2 HP ECM X-13 blower motor. Match horsepower, frame, shaft, rotation, and programmed tap to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect switch, then verify zero voltage with a multimeter.
  2. Access — Remove the blower access panel and slide out the blower assembly if required.
  3. Document — Photograph the motor power and control-tap connections and note the blower wheel position on the shaft.
  4. Remove — Disconnect the harness, loosen the wheel set screw, free the motor from its mount, and remove it.
  5. Install — Mount the new motor, set the blower wheel to the documented position, and reconnect the power and control taps per your photo.
  6. Test — Restore power, run a heat and cool call, and confirm correct rotation, speed, and airflow.

Signs You Need a Replacement

  • Blower won't start or hums without turning.
  • Motor runs at the wrong speed or ignores the board's tap signal.
  • Repeated tripping on thermal overload or weak airflow.
  • Bearing noise, grinding, or burnt-winding odor.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WPG3304040LKC1 | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WPG3304040LKC1 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WPG3304040LKC1 | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.