Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP ECM X-13 1/2 HP Blower Motor Control for WJH336000KTP0A1 — OEM Module | Ships Today
ICP

ICP ECM X-13 1/2 HP Blower Motor Control for WJH336000KTP0A1 — OEM Module | Ships Today

SKU: 1185845 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM ECM X-13 motor control module (part number 1185845) is the 1/2 HP constant-torque blower motor controller for the ICP / Heil / Tempstar WJH336000KTP0A1 packaged heat pump. The X-13 is a programmed electronically commutated motor that holds a steady torque across changing static pressure, delivering quieter operation and lower energy draw than a standard PSC blower. The control module is the brain bolted to the motor end bell — it reads the 24V tap signals from the control board and drives the rotor accordingly. When the module fails, the blower may run at the wrong speed, surge, refuse to start, or trip out entirely, even though the motor itself is good. This OEM module restores correct airflow staging.

Specifications

Spec Value
Part Number 1185845
Type ECM X-13 Constant-Torque Motor Control Module
Brand ICP (Heil / Tempstar / Comfortmaker)
Horsepower 1/2 HP
Motor Type Electronically Commutated (ECM X-13)
Control 24V tap-selected speed staging
Fits Model WJH336000KTP0A1

Compatibility

Built for the ICP WJH336000KTP0A1 packaged heat pump and used across the WJH336000 platform produced by International Comfort Products under the Heil, Tempstar, and Comfortmaker brands. Confirm your existing module is a 1/2 HP ECM X-13 control, part 1185845, before ordering — X-13 modules are matched to a specific motor.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter at the motor leads; ECM capacitors can hold a charge, so wait several minutes.
  2. Access — Remove the blower-access service panel and slide out the blower assembly if needed.
  3. Document — Photograph the high-voltage plug, the 24V control plug, and each tap position before disconnecting.
  4. Remove — Unplug both connectors and unbolt the failed control module from the motor end bell.
  5. Install — Mount the new OEM module to the motor, reseat both plugs, and match the control taps per your photo.
  6. Test — Restore power and verify the blower ramps to the correct speed on heat, cool, and fan calls.

Signs You Need a Replacement

  • Blower won't start or starts then stalls
  • Motor surges, hunts, or runs at the wrong speed
  • Weak or inconsistent airflow at the registers
  • Blower runs constantly or ignores control-board commands

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Fan Motor fit my ICP WJH336000KTP0A1 — OEM Module | Ships Today?
Yes. This is the factory-specified OEM fan motor for the ICP WJH336000KTP0A1 — OEM Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the fan motor on my ICP WJH336000KTP0A1 — OEM Module | Ships Today?
Difficulty: Medium-Hard (1–2 hrs)
Step 1: Turn off breaker. Step 2: Note motor specs: HP, RPM, voltage, rotation direction. Step 3: Remove old motor from mounting. Step 4: Transfer fan blade to new motor. Step 5: Mount new motor, reconnect wiring. Step 6: Restore power, verify rotation direction.
My AC fan isn’t spinning. What part do I need?
Fan not spinning, spinning slowly, or making grinding/squealing noises = motor failure. Grinding = bearings failed. Squealing = bearings dry. No spin + hum = check the motor capacitor first before replacing the entire motor.
Is this fan motor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP fan motor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online