This is the genuine OEM spark igniter (sparker), part number 1184216, for the ICP/Tempstar/Heil RGS180HSAA0AAAA gas furnace. Unlike a hot-surface igniter, a spark igniter generates a high-voltage arc to light the burner gas on each call for heat and, in many designs, also serves as the flame-sensing electrode. When the igniter electrode cracks, the gap drifts, or the ceramic insulator fouls with carbon, the furnace will spark but fail to light, light and then lock out, or short-cycle on flame-proving faults. Replacing this inexpensive component restores reliable ignition.

Specifications

Spec Value
Part Number 1184216
Type Direct Spark Igniter (Sparker)
Brand ICP (Tempstar / Heil)
Function Ignition / flame sensing electrode
Mount OEM bracket-mount at burner

Compatibility

Designed for the ICP/Tempstar/Heil RGS180HSAA0AAAA and related ICP-family furnaces that use direct spark ignition and specify part 1184216. Verify against your unit's parts breakdown, as electrode geometry and gap are model-specific.

Installation Guide

  1. Safety First — Shut off gas and power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, gap, and wire routing before removal.
  4. Remove — Unplug the high-voltage lead and unscrew the old igniter from the burner bracket.
  5. Install — Mount the new igniter, set it to the same position, and reconnect the lead per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm a strong spark and clean light-off.

Signs You Need a Replacement

  • Furnace clicks/sparks but burner won't light
  • Ignition lockout after several failed attempts
  • Cracked ceramic insulator or visibly worn electrode
  • Short-cycling on flame-sense faults

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180HSAA0AAAA — OEM 1184216 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180HSAA0AAAA — OEM 1184216 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180HSAA0AAAA — OEM 1184216 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online