The ICP igniter electrode (OEM part #1179966) is the ignition component for your ICP/Heil/Tempstar RGS240SFFA0AAAA gas furnace. This electrode generates the spark that lights the burner assembly on each heating call. Over time the electrode tip erodes, cracks, or accumulates carbon, which leads to no ignition, repeated ignition lockouts, or a furnace that cycles on the inducer but never produces heat. Replacing a worn igniter electrode restores reliable, on-demand burner ignition and eliminates the nuisance lockouts that leave your home cold.

Specifications

Spec Value
Part Number 1179966
Description Igniter / Ignitor Electrode
Type Direct Spark Electrode
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS240SFFA0AAAA
Fitment OEM Direct Replacement

Compatibility

This igniter electrode is a direct OEM fit for the ICP/Heil/Tempstar RGS240SFFA0AAAA gas furnace and other RGS-series models that call out part 1179966. Always confirm your existing part number against the unit rating plate before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower/burner service panel.
  3. Document — Photograph the electrode position, ignition wire routing, and ground strap before disconnecting.
  4. Remove — Disconnect the high-voltage ignition lead, remove the mounting screw(s), and lift the old electrode from the burner bracket.
  5. Install — Mount the new electrode, set the correct spark gap per the burner spec, and reconnect the ignition lead and ground exactly as photographed.
  6. Test — Restore gas and power, then run a full heat cycle to confirm clean spark, burner light-off, and flame proof.

Signs You Need a Replacement

  • Furnace inducer runs but burners never ignite
  • Repeated ignition lockouts or hard-start cycling
  • Weak, intermittent, or no visible spark at the electrode
  • Cracked ceramic insulator or eroded/carbon-fouled electrode tip

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SFFA0AAAA — OEM 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SFFA0AAAA — OEM 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SFFA0AAAA — OEM 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.