This genuine OEM defrost control board (Part #1069364) is the brain of the defrost cycle on the ICP/Tempstar/Heil YL036GB1 heat pump. In heating mode, frost and ice build on the outdoor coil; the defrost board monitors coil temperature and elapsed run time, then commands the reversing valve and condenser fan to melt that ice and restore efficiency. It coordinates the compressor contactor, the 24V reversing valve coil, the defrost sensor, and the auxiliary/emergency heat call. When this board fails, the heat pump may ice over solid, run a never-ending defrost, blow cold air during heating, or refuse to switch between heating and cooling. Because the board governs both comfort and equipment protection, a failing unit should be replaced promptly.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Defrost timing, reversing valve & fan control
Fits Model YL036GB1

Compatibility

Direct factory replacement for the ICP/Tempstar/Heil YL036GB1 outdoor heat pump. The same board services numerous related ICP-family heat-pump condensers that share this defrost control platform. Match the OEM part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the condenser control-panel cover to reach the board.
  3. Document — Photograph every harness, plug, and spade terminal before unplugging.
  4. Remove — Unplug the wiring connectors, release the standoffs or screws, and lift out the old board.
  5. Install — Snap in the new board and reconnect each connector exactly per your photo.
  6. Test — Restore power and confirm normal heating, cooling, and a clean defrost cycle.

Signs You Need a Replacement

  • Outdoor coil icing over and never defrosting
  • Heat pump stuck in continuous defrost or blowing cold air in heat mode
  • Unit won't switch between heating and cooling
  • No 24V output to the reversing valve or fan during defrost

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YL036GB1 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YL036GB1 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YL036GB1 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.