This OEM defrost control board (part #34332101) is the brain of the defrost cycle on your ICP/Tempstar/Heil YK036GC2 heat pump. It monitors coil temperature and run time, then initiates and terminates the defrost mode that clears frost and ice from the outdoor coil in heating season. It also coordinates the reversing valve, compressor, and outdoor fan during defrost. When this board fails, the heat pump may ice over, fail to defrost, lock out, run the wrong mode, or stop heating entirely. Replacing it restores correct defrost timing and efficient heat pump operation.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat Pump Defrost Management

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil YK036GC2 heat pump and compatible single-stage ICP-family outdoor units that use this defrost control. Match your existing board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-box service panel on the condensing unit.
  3. Document — Photograph every wire and connector position on the old board before disconnecting.
  4. Remove — Unplug the wiring harnesses, release the board standoffs/screws, and remove the failed board.
  5. Install — Seat the new board on its standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a heating cycle, and confirm the unit completes a normal defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts
  • Heat pump locks out or won't switch into heating
  • Reversing valve or fan behaves incorrectly during defrost
  • No 24V output to compressor/fan terminals on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK036GC2 — Heat Pump OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK036GC2 — Heat Pump OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK036GC2 — Heat Pump OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online