Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YK036G — Heat Pump Timer Board | Ships Today
ICP

ICP Defrost Control Board for YK036G — Heat Pump Timer Board | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part number 34332101) governs the defrost cycle on your ICP, Tempstar, and Heil YK036G heat pump. In heating mode, ice forms on the outdoor coil and chokes off airflow. The defrost board watches coil temperature and accumulated run time, then briefly switches the reversing valve and outdoor fan to melt that ice before returning to heating. A failed 24V board leaves the coil iced over, locks the unit out of defrost, causes short-cycling, or stops heat output entirely. A new board restores proper defrost timing and shields the compressor from liquid refrigerant slugging.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Defrost timing & reversing valve control
Fitment OEM replacement

Compatibility

Engineered as a direct OEM replacement for the ICP/Tempstar/Heil YK036G heat pump and other units that originally shipped with defrost control board 34332101. Always confirm your existing board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Label and unplug each connector, release the board mounting standoffs/screws, and lift out the old defrost board.
  5. Install — Mount the new 34332101 board, then reconnect every wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the unit heats normally and initiates/terminates defrost correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears during heating
  • Heat pump never enters or never exits defrost mode
  • Reversing valve fails to switch on the defrost cycle
  • Short-cycling, no heat, or burnt/corroded board components

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK036G — Heat Pump Timer Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK036G — Heat Pump Timer Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK036G — Heat Pump Timer Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.