Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YK030G2 — Heat Pump Module | Ships Today
ICP

ICP Defrost Control Board for YK030G2 — Heat Pump Module | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part number 34332101) is the electronic brain that manages the defrost cycle on your ICP / Heil / Tempstar YK030G2 heat pump. It monitors the defrost thermostat and ambient conditions, then periodically reverses the unit to melt frost and ice off the outdoor coil so the system can keep extracting heat efficiently in cold weather. The board sequences the reversing valve, controls the compressor and outdoor fan during defrost, and energizes auxiliary heat at the right moments. When this board fails, the heat pump may ice over solid, blow cold air on a heat call, short-cycle, fail to enter or exit defrost, or stop responding to the thermostat entirely. Because it coordinates several high-cost components, a failing defrost board can masquerade as a much bigger problem — replacing the board is usually the correct, economical fix.

Specifications

Spec Value
OEM Part Number 34332101
Type Defrost Control Board
Control Voltage 24V
Function Defrost timing, reversing valve & aux heat control
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model YK030G2

Compatibility

A direct OEM replacement for the ICP YK030G2 heat pump and shared across compatible Heil, Tempstar, and Comfortmaker outdoor units using this defrost board. Match the existing board's part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the control-box service panel on the condensing unit.
  3. Document — Photograph every wire, plug, and terminal on the existing board before unplugging.
  4. Remove — Unplug the harness connectors and unscrew or unclip the old board from its standoffs.
  5. Install — Mount the new board and reconnect each plug and lead exactly per your photo.
  6. Test — Restore power and confirm the heat pump heats normally and initiates/terminates defrost correctly.

Signs You Need a Replacement

  • Outdoor coil ices or frosts over and never defrosts
  • Heat pump blows cold air on a call for heat
  • Unit short-cycles or won't switch between heat and defrost
  • No response from the outdoor unit despite a thermostat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK030G2 — Heat Pump Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK030G2 — Heat Pump Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK030G2 — Heat Pump Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online