Overview

This genuine OEM defrost control board (part 34332101) is the brain of the defrost cycle on the ICP / Tempstar / Heil YK024GC2 heat pump. It monitors coil temperature and run time, then initiates and terminates defrost — reversing the valve, shutting off the outdoor fan, and energizing auxiliary heat so frost is cleared from the outdoor coil in winter. A failed defrost board lets ice build up on the coil, kills heating capacity, can trip the unit on high pressure, or strands the system in continuous defrost. Replacing it with a factory board restores correct, timed defrost behavior and protects the compressor.

Specifications

Spec Value
Part Number 34332101
Type Defrost control board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat pump defrost control
Fitment OEM replacement

Compatibility

Built for the ICP/Tempstar/Heil YK024GC2 heat pump and related models that use this defrost control board. Match the OEM part number printed on your existing board before ordering, as defrost timing and terminal layouts vary between revisions.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control panel to expose the board.
  3. Document — Photograph every wire and connector position and note the defrost-time jumper/pin setting.
  4. Remove — Unplug the connectors, release the board standoffs, and lift the old board out.
  5. Install — Mount the new board, set the defrost timing jumper to match the original, and reconnect each lead per your photo.
  6. Test — Restore power, run a heating call, and verify the board initiates and terminates defrost correctly.

Signs You Need a Replacement

  • Heavy ice or frost build-up on the outdoor coil
  • Unit stuck in or never entering defrost
  • Weak heating output or high-pressure trips in cold weather
  • No response from the defrost test pins or burned board traces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK024GC2 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK024GC2 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK024GC2 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online