Overview

This genuine ICP defrost control board (OEM part 34332101) is the brain that manages the defrost cycle on your YK024G2 heat pump. Using the defrost thermostat and an internal timer, it decides when to reverse the system, shut off the outdoor fan, and clear frost from the outdoor coil, then returns the unit to normal heating. A failed defrost board lets ice build up on the coil — choking airflow and slashing heating capacity — or it can lock the unit into constant defrost. Because the board also routes the 24V control and reversing-valve signals, a fault here can mimic many other failures.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24 VAC
Function Heat Pump Defrost Timing & Sequencing
Fit OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP YK024G2 heat pump and other ICP-family units (Tempstar, Heil, Comfortmaker) using this defrost board. Match the board's part number and connector layout to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-panel cover to reach the board.
  3. Document — Photograph every harness and terminal connection before disconnecting.
  4. Remove — Unplug the connectors, release the standoffs or screws, and lift the old board out.
  5. Install — Seat the new board on its standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power, confirm normal heating, and verify a defrost cycle initiates and terminates correctly.

Signs You Need a Replacement

  • Heavy ice or frost building up on the outdoor coil
  • Unit stuck in continuous defrost or never defrosts
  • Outdoor fan or reversing valve not sequencing on defrost
  • Weak heating output despite a clean coil and good charge

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK024G2 — Heat Pump Timer | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK024G2 — Heat Pump Timer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK024G2 — Heat Pump Timer | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.