This OEM defrost control board (part number 34332101) is the brain of the defrost cycle on your ICP, Tempstar, and Heil YK024G1 heat pump. It monitors outdoor coil temperature and elapsed run time, then commands the reversing valve and shuts the outdoor fan to melt frost off the coil during cold-weather operation. When this board fails, the heat pump may ice over, run continuously, fail to switch between heating and cooling, or stop defrosting entirely — leading to poor heating performance and potential compressor damage. Replacing the defrost board restores proper, efficient heat-pump operation.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Heat Pump Defrost Timing & Reversing Valve Control

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil YK024G1 heat pump. Also used across comparable Comfortmaker and Heil branded heat pumps that share the same defrost control platform. Verify the board's part number and connector layout against your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser/heat-pump service panel to reach the control board.
  3. Document — Photograph every plug and wire on the board before disconnecting.
  4. Remove — Unplug the wiring harnesses, release the standoffs/screws, and lift out the old board.
  5. Install — Mount the new board and reconnect each harness to the matching terminal per your photo.
  6. Test — Restore power and confirm the unit completes a normal call and initiates a test defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts in heat mode
  • Heat pump won't switch between heating and cooling
  • Unit runs constantly with weak heating output
  • No response to thermostat calls or erratic cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK024G1 — Heat Pump Timer | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK024G1 — Heat Pump Timer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK024G1 — Heat Pump Timer | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online