The ICP defrost control board (OEM #34332101) governs the defrost cycle on your ICP/Heil/Tempstar YK018GC2 heat pump. It tracks outdoor coil temperature and accumulated run time, then commands the reversing valve and outdoor fan to melt frost off the outdoor coil in cold weather. Running on 24V control voltage, this board is critical to winter heat-pump performance — a failure typically shows up as a frozen outdoor unit, a system that runs constantly without keeping up, or expensive auxiliary heat that never cycles off.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP YK018GC2 heat pump and many ICP-family condensing units sold under the Heil, Tempstar, and Comfortmaker brands. Confirm your existing board carries part number 34332101 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's control panel cover.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and unplug each connector, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board on the standoffs and reconnect every wire exactly per your photo.
  6. Test — Restore power and confirm the unit completes a normal defrost cycle and returns to heating.

Signs You Need a Replacement

  • Outdoor coil ices over and won't clear
  • Heat pump runs nonstop but can't maintain temperature
  • Auxiliary/emergency heat stays energized constantly
  • No defrost-fan or reversing-valve response in cold weather

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK018GC2 — 24V Heat Pump Defrost | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK018GC2 — 24V Heat Pump Defrost | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK018GC2 — 24V Heat Pump Defrost | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online