Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YK018G2 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for YK018G2 — Heat Pump | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM defrost control board (part #34332101) for the ICP/Tempstar/Heil YK018G2 heat pump. The defrost board monitors outdoor coil temperature and run time, then energizes the reversing valve and stops the outdoor fan to melt frost off the coil during heating season. It also coordinates compressor timing and auxiliary/emergency heat staging. When the board fails, the heat pump can ice over solid, run continuous unnecessary defrost cycles, fail to switch into defrost at all, or lose proper compressor and fan control — all of which kill efficiency and comfort.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Function Defrost timing, reversing valve & fan control
Application Heat pump outdoor unit
Fitment OEM Replacement

Compatibility

Designed for the ICP/Tempstar/Heil YK018G2 heat pump and related ICP-family heat pumps that use defrost board 34332101. Match the OEM part number and connector layout to your original board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-box service panel.
  3. Document — Photograph every plug, sensor, and wire on the board before disconnecting.
  4. Remove — Unplug the connectors and defrost sensor, release the standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the same standoffs, reconnect each plug and the defrost sensor per your photo, and set any DIP/jumper defrost-interval settings to match the original.
  6. Test — Restore power, run a heating call, and confirm normal operation and (where applicable) a forced defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and won't defrost
  • Unit runs constant or excessive defrost cycles
  • No reversing valve or fan response during defrost
  • Erratic compressor staging or no heat-pump heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YK018G2 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YK018G2 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YK018G2 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart