This OEM defrost control board (part 1069364) is the brain of the defrost cycle in your ICP / Tempstar / Heil YJ048GA2 heat pump. It monitors coil temperature and run time, then initiates and terminates defrost so frost is cleared from the outdoor coil during cold-weather operation. The board also coordinates the reversing valve, condenser fan, and compressor timing during the cycle. When a defrost board fails, the outdoor coil ices over, heating efficiency collapses, and you may see the unit short-cycle or never defrost at all. A direct-replacement board restores proper defrost timing and protects the compressor.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Function Defrost timing, reversing valve & fan control
Control Voltage 24V
Fitment OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil YJ048GA2 heat pump and other ICP-family outdoor units that use the 1069364 defrost board. Match the part number and connector layout to your original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit control-panel cover to reach the board.
  3. Document — Photograph every wire and plug-in connector and note the defrost timing pin/jumper setting.
  4. Remove — Unplug the connectors, release the mounting standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, transfer all connectors per your photo, and set the defrost timing jumper to match the original.
  6. Test — Restore power, run a heat call, and confirm normal operation and a forced/initiated defrost cycle completes correctly.

Signs You Need a Replacement

  • Outdoor coil ices up and never defrosts
  • Heat pump short-cycles or won't switch into defrost
  • Reversing valve or fan misbehaves during the cycle
  • Visible burnt traces, scorch marks, or a relay stuck on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ048GA2 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ048GA2 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ048GA2 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.