This is a genuine OEM defrost control board (Part Number 1069364) for the ICP / Heil / Tempstar YJ048GA1 heat pump. The defrost board is the brain of the outdoor unit's heat-pump operation — it monitors the defrost thermostat and timer, energizes the reversing valve and compressor contactor, and periodically reverses the cycle to melt frost off the outdoor coil during heating. A failed board leaves the outdoor coil iced over, kills heating capacity, and can lock out the compressor entirely. Typical failure signs include the outdoor unit staying caked in ice during heat mode, no defrost cycle ever initiating, the unit failing to switch between heat and cool, or burnt relays and scorch marks on the board.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP (Heil / Tempstar / Comfortmaker)
Function Heat-Pump Defrost Timing & Reversing Valve Control
Control Voltage 24V
Fitment OEM

Compatibility

Designed as a direct OEM replacement for the ICP/Heil/Tempstar YJ048GA1 heat pump and related ICP-family outdoor units using this defrost board. Verify the original board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser/heat-pump electrical access panel.
  3. Document — Photograph every wire harness, plug, and terminal on the existing board before disconnecting.
  4. Remove — Unplug the connectors, release the board standoffs or screws, and lift out the old board.
  5. Install — Seat the new board on the standoffs and reconnect each harness to the matching terminal per your photos.
  6. Test — Restore power, initiate a defrost (or jumper the test pins per the board legend), and confirm the reversing valve and compressor respond correctly.

Signs You Need a Replacement

  • Outdoor coil ices over in heat mode and never defrosts.
  • No defrost cycle initiates regardless of outdoor temperature.
  • Unit won't switch the reversing valve between heating and cooling.
  • Visible burnt relays, melted connectors, or scorch marks on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ048GA1 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ048GA1 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ048GA1 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online