Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YJ036GA1 — Heat Pump 24V | Ships Today
ICP

ICP Defrost Control Board for YJ036GA1 — Heat Pump 24V | Ships Today

SKU: 1069364 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM defrost control board (part number 1069364) is the brain of the defrost cycle for the ICP/Tempstar/Heil YJ036GA1 heat pump. During heating mode, frost builds up on the outdoor coil and must be periodically melted off. The defrost board monitors coil temperature and elapsed run time, then commands the reversing valve, energizes auxiliary heat, and stops the outdoor fan to run a defrost cycle before returning the system to normal heating. When this board fails, the unit can ice over solid in winter, fail to come out of defrost, short-cycle, or lose heating entirely. Because it controls the 24V low-voltage logic for the whole outdoor unit, a failed board often presents as multiple seemingly unrelated symptoms.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fits Model YJ036GA1

Compatibility

Direct-fit replacement defrost control board for the ICP/Tempstar/Heil YJ036GA1 heat pump and other ICP family outdoor units that originally shipped with part 1069364. Verify the original board's part number and terminal layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel on the outdoor unit.
  3. Document — Photograph every wire and connector on the existing board before removing anything.
  4. Remove — Unplug the connectors and low-voltage leads, then unclip or unscrew the old board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each wire and connector exactly per your photo.
  6. Test — Restore power, initiate a heat call, and confirm normal operation and a proper defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never defrosts in heating mode.
  • Unit gets stuck in defrost or short-cycles between modes.
  • No heating output even though the compressor and fan run.
  • Reversing valve or auxiliary heat fails to activate on schedule.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ036GA1 — Heat Pump 24V | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ036GA1 — Heat Pump 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ036GA1 — Heat Pump 24V | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online