This is the genuine OEM defrost control board (part number 34332101) for the ICP / Heil / Tempstar YJ036G1 heat pump. The defrost board is the brain of the outdoor unit in heating mode: it monitors the defrost thermostat and run time, then initiates and terminates defrost cycles, energizes the reversing valve solenoid, and switches the condenser fan and compressor as needed to clear frost from the outdoor coil. A failed defrost board causes the most common cold-weather heat pump complaints — a coil that ices over solid, a unit that never defrosts (or defrosts constantly), or a system that loses heating capacity. Replacing the board restores proper defrost timing and protects the compressor from running against a blocked, iced coil.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24 VAC
Function Defrost timing, reversing valve & fan control
Fitment OEM Replacement

Compatibility

Direct factory replacement for the defrost control board in the ICP / Heil / Tempstar YJ036G1 heat pump and related ICP-family outdoor units that use this board. Match the part number and connector layout to your original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the control box.
  3. Document — Photograph every connector and wire on the existing board before disconnecting.
  4. Remove — Unplug the harnesses, release the board's mounting standoffs or screws, and lift out the old board.
  5. Install — Seat the new board on the standoffs, then reconnect each harness to its matching terminal per your photo (note defrost sensor, reversing valve, fan, and 24V connections).
  6. Test — Restore power and confirm normal heating operation; initiate a test/forced defrost if the board supports it to verify the cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears in heating mode
  • Unit defrosts too frequently or stays in defrost too long
  • Reversing valve or condenser fan not energizing on schedule
  • Loss of heating capacity or short-cycling in cold weather

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ036G1 — Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ036G1 — Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ036G1 — Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.