This OEM defrost control board (part number 34332101) is the brain of the defrost cycle in your ICP Tempstar Heil YJ036G heat pump. In heating mode, frost builds on the outdoor coil and must be periodically melted off so the system keeps absorbing heat. The defrost board monitors the defrost thermostat and run time, then commands the reversing valve and fan to run a timed or demand defrost, restoring efficiency. When this board fails, the heat pump can ice over completely, run continuously without defrosting, defrost too often, or lose backup-heat staging. Symptoms include a frozen outdoor unit, weak heating, and short cycling. This is a direct OEM-spec replacement board.
| Spec | Value |
|---|---|
| Part Number | 34332101 |
| Type | Defrost Control Board |
| Brand | ICP (Tempstar / Heil) |
| Function | Heat Pump Defrost Timing & Control |
| Application | Heat Pump Outdoor Unit |
| Fit | OEM Replacement |
Designed for the ICP Tempstar Heil YJ036G heat pump and other ICP-family outdoor units that use the 34332101 defrost control board. Match the board's connector layout and defrost-interval jumper options to your existing board before installing.