Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YJ036G — Heat Pump Timer | Ships Today
ICP

ICP Defrost Control Board for YJ036G — Heat Pump Timer | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part number 34332101) is the brain of the defrost cycle in your ICP Tempstar Heil YJ036G heat pump. In heating mode, frost builds on the outdoor coil and must be periodically melted off so the system keeps absorbing heat. The defrost board monitors the defrost thermostat and run time, then commands the reversing valve and fan to run a timed or demand defrost, restoring efficiency. When this board fails, the heat pump can ice over completely, run continuously without defrosting, defrost too often, or lose backup-heat staging. Symptoms include a frozen outdoor unit, weak heating, and short cycling. This is a direct OEM-spec replacement board.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Function Heat Pump Defrost Timing & Control
Application Heat Pump Outdoor Unit
Fit OEM Replacement

Compatibility

Designed for the ICP Tempstar Heil YJ036G heat pump and other ICP-family outdoor units that use the 34332101 defrost control board. Match the board's connector layout and defrost-interval jumper options to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser control-panel cover to expose the board.
  3. Document — Photograph every wire harness, plug, and the defrost-timer jumper setting before disconnecting.
  4. Remove — Unplug the connectors, release the mounting standoffs or screws, and lift the old board out.
  5. Install — Mount the new board, set the defrost interval jumper to match the original, and reconnect each harness per your photo.
  6. Test — Restore power, run heating mode, and verify a normal defrost cycle initiates and terminates correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts in heating mode.
  • Heat pump defrosts far too often or at the wrong times.
  • No reversing-valve or fan response during the defrost cycle.
  • Burn marks, scorched traces, or a non-responsive board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ036G — Heat Pump Timer | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ036G — Heat Pump Timer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ036G — Heat Pump Timer | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.