This OEM defrost control board (part number 1069364) is the brain of the defrost cycle on your ICP YJ024GA3 heat pump. In heating mode the board monitors the defrost thermostat and run time, then periodically reverses the valve and shuts off the outdoor fan to melt frost off the coil before returning to normal heating. A failed defrost board is a frequent cause of an outdoor coil icing over, a unit that never defrosts, or one that defrosts far too often and short-cycles. The board also coordinates the contactor, reversing valve coil, and fan, so a fault here can cascade into apparent compressor or airflow problems.
| Spec | Value |
|---|---|
| Part Number | 1069364 |
| Type | Defrost Control Board |
| Brand | ICP / Heil / Tempstar |
| Function | Defrost timing, reversing valve & fan control |
| Application | Heat pump outdoor unit |
Designed for the ICP YJ024GA3 heat pump and compatible ICP-family (Heil, Tempstar, Comfortmaker) outdoor units. Match the board's part number and connector layout to your existing board before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.