This OEM defrost control board (part number 1069364) is the brain of the defrost cycle on your ICP YJ024GA1 heat pump. In heating mode, frost and ice build up on the outdoor coil; the defrost board monitors the coil temperature sensor and accumulated run time, then periodically reverses the system into a short defrost cycle to melt that ice and protect efficiency. It coordinates the reversing valve, compressor, outdoor fan, and auxiliary heat, and manages the 24V control timing for the whole sequence. When the board fails, the outdoor coil ices over and stays frozen, heating output drops, the unit may short cycle, or defrost may run constantly. A failed board is a common cause of poor heat-pump performance in cold weather.

Specifications

Spec Value
OEM Part Number 1069364
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fits Model YJ024GA1

Compatibility

Designed as a direct OEM replacement for the ICP / Tempstar / Heil YJ024GA1 heat pump. The same defrost board services many comparable ICP-family and Comfortmaker heat-pump condensing units of the same generation. Confirm the original part number 1069364 and the wiring terminal layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the condensing unit service panel to reach the control box.
  3. Document — Photograph every wire and connector on the board before disconnecting, including the coil sensor and reversing valve leads.
  4. Remove — Unplug the harnesses, release the board standoffs or screws, and lift the old board out.
  5. Install — Mount the new board, reconnect each harness and sensor exactly as photographed, and set any defrost-time jumper to match the original.
  6. Test — Restore power and run a heating cycle; confirm normal operation and, if needed, initiate a forced defrost to verify the cycle completes.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears in heating mode.
  • Heat pump runs but delivers weak or no heat in cold weather.
  • Unit short cycles or gets stuck in continuous defrost.
  • Reversing valve or auxiliary heat fails to engage on schedule.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YJ024GA1 — Heat Pump OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YJ024GA1 — Heat Pump OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YJ024GA1 — Heat Pump OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online