This OEM defrost control board (ICP part number 1069364) governs the defrost cycle on your ICP/Tempstar/Heil YG048GB1 heat pump. It reads coil temperature and accumulated run time, then starts and ends defrost to clear ice from the outdoor coil during heating. The board sequences the reversing valve, compressor, and outdoor fan, and signals the indoor unit for auxiliary heat. A defective defrost board is the most common reason a heat pump ices over, blows cold air in heating mode, or never exits a frozen state. The board runs on a 24V control circuit with defrost timing pins and a coil temperature sensor input.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat Pump Defrost
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil YG048GB1 heat pump and other ICP-family units that originally shipped with defrost board 1069364. Always match the part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's control-box service panel.
  3. Document — Photograph all wiring, connectors, and defrost timing pin settings before disconnecting.
  4. Remove — Label and unplug the low-voltage and sensor connectors, then unscrew the old board from its standoffs.
  5. Install — Mount the new board, set the defrost timing pins to match the original, and reconnect every wire and the coil sensor.
  6. Test — Restore power and run a heating/defrost cycle to verify defrost initiates and terminates correctly.

Signs You Need a Replacement

  • Outdoor coil freezes and never defrosts
  • Heat pump blows cold air while in heating mode
  • Defrost cycle runs too long or never ends
  • Burned, corroded, or unresponsive control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG048GB1 — Heat Pump 24V Defrost | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG048GB1 — Heat Pump 24V Defrost | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG048GB1 — Heat Pump 24V Defrost | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online