Overview

This genuine OEM defrost control board (part number 1069364) regulates the defrost cycle on your ICP / Heil / Tempstar YG042GA1 heat pump. The board monitors coil temperature and run time, then commands the reversing valve and shuts down the outdoor fan to melt frost off the outdoor coil during cold-weather operation. When this board fails, the system either stops defrosting (ice builds on the coil and heating capacity collapses) or defrosts constantly (poor efficiency and short cycling). It operates on a standard 24V control signal and includes the timing and temperature logic needed for reliable heat-pump heating.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Heat Pump Defrost
Fits Model YG042GA1

Compatibility

Engineered as a direct-fit replacement for the ICP, Heil, Comfortmaker, and Tempstar YG042GA1 heat pump. Always confirm the existing board part number and terminal layout against 1069364 before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical access panel.
  3. Document — Photograph every wire and terminal connection before disconnecting anything.
  4. Remove — Label and unplug the low-voltage and sensor leads, then remove the mounting screws and lift out the old defrost board.
  5. Install — Mount the new 1069364 board, reconnect each wire exactly per your photo, and seat the defrost thermostat/sensor.
  6. Test — Restore power and verify a normal heating call and a forced defrost cycle complete correctly.

Signs You Need a Replacement

  • Heavy ice or frost building on the outdoor coil during heating
  • Heat pump never enters or never exits defrost mode
  • Constant short cycling between heat and defrost
  • No 24V output to the reversing valve or fan during defrost

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG042GA1 — OEM Heat Pump Part 1069364 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG042GA1 — OEM Heat Pump Part 1069364 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG042GA1 — OEM Heat Pump Part 1069364 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.