Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YG030GC2 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for YG030GC2 — Heat Pump | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part number 34332101) governs the defrost cycle on your ICP / Tempstar / Heil YG030GC2 heat pump. During heating, frost accumulates on the outdoor coil; the defrost board watches coil temperature and accumulated run time, then triggers a reversing-valve switch and stops the outdoor fan to clear the ice before resuming normal heat. It also enforces compressor anti-short-cycle timing. A failed board shows up as an outdoor coil iced over solid, a unit that never enters or never exits defrost, loss of heat-pump heating, or the system defaulting to constant emergency/auxiliary heat.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Defrost timing, reversing valve & fan control, compressor protection
Application Heat Pump (outdoor unit)

Compatibility

Direct OEM replacement for the defrost control board in the ICP Tempstar Heil YG030GC2 heat pump. This board is used across a range of ICP-family outdoor heat pump units. Verify the connector layout and part number against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph every wire and connector on the existing board before removing anything.
  4. Remove — Unplug the harness connectors and unscrew or unclip the old board from its standoffs.
  5. Install — Mount the new board and reconnect each connector and wire exactly per your photo.
  6. Test — Restore power, run a heating call, and confirm proper defrost initiation and termination.

Signs You Need a Replacement

  • Outdoor coil freezes over and never clears
  • System stuck in defrost or never enters defrost
  • No heat-pump heating; constant auxiliary/emergency heat
  • Erratic compressor or outdoor-fan behavior in heating mode

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG030GC2 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG030GC2 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG030GC2 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online