Overview

This OEM defrost control board (part number 34332101) is the brain of the defrost cycle on your ICP YG030GC1 heat pump. In heating mode the outdoor coil collects frost, and this board monitors run time and coil temperature to periodically reverse the system into defrost, clearing ice so the unit keeps heating efficiently. It also coordinates the reversing valve, fan, and auxiliary heat during the cycle. When the board fails, the outdoor coil ices over, heating output drops, the unit may short-cycle, or it never enters or never exits defrost. Replacing the board restores proper defrost timing and protects efficiency and the compressor.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Function Heat Pump Defrost Timing & Sequencing
Application Heat Pump Outdoor Unit

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil YG030GC1 heat pump and shared across ICP-family outdoor units that use defrost board 34332101. Verify the printed part number and connector layout against your original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to reach the control box.
  3. Document — Photograph every connector, plug, and wire on the existing board before unplugging.
  4. Remove — Unplug the wire harnesses, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect each harness and sensor lead exactly per your photos, including the defrost sensor.
  6. Test — Restore power, run a heating cycle, and confirm normal operation; initiate a forced defrost if your board supports the test pins.

Signs You Need a Replacement

  • Outdoor coil freezes over and won't defrost
  • Unit stuck running in defrost or never entering defrost
  • Weak heating output or frequent short-cycling in heat mode
  • Reversing valve or outdoor fan not sequencing correctly

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG030GC1 — Heat Pump Timer | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG030GC1 — Heat Pump Timer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG030GC1 — Heat Pump Timer | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.