Overview

The 1069364 Defrost Control Board is the OEM control that manages the defrost cycle on the ICP / Tempstar / Heil YG024GC9 heat pump. It tracks outdoor coil temperature and compressor run time, then commands a defrost when ice builds on the outdoor coil — energizing the reversing valve, dropping the outdoor fan, and signaling auxiliary heat so supply air stays warm. It also coordinates the compressor contactor during normal operation. A failed board leaves the coil to freeze solid, causes erratic or constant defrosts, or kills heating entirely. This is a direct OEM replacement matched to the YG024GC9's terminal layout and defrost timing, ensuring the system protects itself in cold weather exactly as designed.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Function Defrost timing, reversing valve & contactor control
Fitment OEM direct replacement

Compatibility

Built for the ICP Tempstar Heil YG024GC9 heat pump and ICP-family outdoor units that shipped with defrost board 1069364. Confirm the printed part number on your current board before ordering, since ICP used several defrost boards across model years.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's control-panel service cover.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Unplug the low-voltage harness, sensor leads, and high-voltage terminals, then unscrew the old board from its standoffs.
  5. Install — Mount the new 1069364 board, reconnect each wire per your photos, and firmly seat the defrost sensor lead.
  6. Test — Restore power, run a heating cycle, and observe a defrost to confirm the reversing valve and fan respond.

Signs You Need a Replacement

  • Outdoor coil freezes and never clears
  • Unit defrosts too often or not at all
  • No auxiliary heat during defrost cycles
  • Reversing valve or outdoor fan ignores board commands

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG024GC9 — 1069364 Heat Pump Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG024GC9 — 1069364 Heat Pump Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG024GC9 — 1069364 Heat Pump Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online